Repository logo
  • Research Outputs
  • Researchers
  • Schools
    Felizberta Lo Padilla Tong School of Social SciencesIp Ying To Lee Yu Yee School of Humanities and LanguagesRita Tong Liu School of Business and Hospitality ManagementS.K. Yee School of Health SciencesYam Pak Charitable Foundation School of Computing and Information Sciences
  • Help
Repository logo
  1. Home
  2. Health Sciences
  3. HS Publication
  4. Effect of continuous oral suctioning on the development of ventilator-associated pneumonia: A pilot randomized controlled trial
 
  • Details

Effect of continuous oral suctioning on the development of ventilator-associated pneumonia: A pilot randomized controlled trial

Author(s)
Chow, Meyrick Chum Ming  
Author(s)
Kwok, S.-M.
Luk, H.-W.
Law, J. W. H.
Leung, B. P. K.
Date Issued
2012
Publisher
Elsevier
Journal
International Journal of Nursing Studies
Volume
49
Issue
11
Start page
1333
End page
1341
Abstract
Background Both continuous and intermittent aspiration of subglottic secretions by means of specially designed endotracheal tubes containing a separate dorsal lumen that opens into the subglottic region have been shown to be useful in reducing ventilator-associated pneumonia (VAP). However, the high cost of these tubes restricts their use. Objective The aim of this pilot randomized controlled trial was to test the effect of a low-cost device (saliva ejector) for continuous oral suctioning (COS) on the incidence of VAP in patients receiving mechanical ventilation. Methods The study was conducted in the six-bed medical-surgical ICU of a hospital with over 400 beds that provides comprehensive medical services to the public. The design of this study was a parallel-group randomized controlled trial. While both the experimental and control groups used the conventional endotracheal tube, the saliva ejector was only applied to patients assigned to the experimental group. The device was put between the patient's cheek and teeth, and then connected to 100 mmHg of suction for the continuous drainage of saliva. Results Fourteen patients were randomized to receive COS and 13 patients were randomized to the control group. The two groups were similar in demographics, reasons for intubation, co-morbidity, and risk factors for acquiring VAP. VAP was found in 3 patients (23.1%; 71 episodes of VAP per 1000 ventilation days) receiving COS and in 10 patients (83.3%; 141 episodes of VAP per 1000 ventilation days) in the control group (relative risk, 0.28; 95% confidence interval, 0.10–0.77; p = 0.003). The duration of mechanical ventilation in the experimental group was 3.2 days (SD 1.3), while that in the control group was 5.9 days (SD 2.8) (p = 0.009); and the length of ICU stay was 4.8 days (SD 1.6) versus 9.8 days (SD 6.3) for the experimental and control groups, respectively (p = 0.019). Conclusion Continuous clearance of oral secretion by the saliva ejector may have an important role to play in reducing the rate of VAP, decreasing the duration of mechanical ventilation, and shortening the length of stay of patients in the ICU.
URI
https://repository.sfu.edu.hk/handle/sfu/4592
DOI
10.1016/j.ijnurstu.2012.06.003
SFU Affiliated Publication
No
Availability at SFU Library

No database links found.

Responsible Use of E‑Resources | Privacy Policy | Disclaimer
© SFU Library. All Rights Reserved.
SFU Library